Read two manufacturers’ tables to compare indoor-unit widths, check sound levels at a named fan setting and find the electrical input for a complete split system.

Compare the casing widths

Read across the width row in Daikin’s FTXTM-A indoor-unit table. FTXTM30A2V1B is 804 mm wide and FTXTM40A2V1B is 997 mm wide. The second casing therefore needs 193 mm more wall width. To check a particular space, also look up the installation clearances for the exact model in its installation manual.[1]

Read the sound level and fan setting together

In cooling mode the FTXTM30A2V1B has a sound power level of 60 dB(A). To compare fan settings, move to the sound pressure level rows for that same model and mode. Daikin lists 45 dB(A) on high and 21 dB(A) in silent operation. When comparing two models, use the same quantity and check the fan setting and measurement conditions.[1]

Check which units the input figure covers

In Mitsubishi Electric’s manual, page EN-6, pair indoor model MSZ-AP25VG with outdoor model MUZ-AP25VG. In the cooling column, 2.5 kW is the cooling capacity and 0.60 kW is the pair’s electrical input. The rating uses 27 °C dry bulb and 19 °C wet bulb indoors, and 35 °C dry bulb outdoors. Keep both model codes and these temperatures with the figures when you compare a quotation.[2]

Source documentation

  1. Daikin UK · FTXTM-A, dimensions and sound levelswww.daikin.co.uk