| City & 1% summer design day | Berlin (DE) · 1% 30.6 °C · 30.0 °C / 37% RH @ 15:00 local time (CEST · UTC+2) | Static city files from GeoNames (CC BY 4.0) and PVGIS 5.3 (PVGIS-SARAH3 / ERA5, 2005–2023): 1% exceedance design day & May–September TMY (computed in UTC internally, displayed in local time). |
| Walls, roof, glazing & shading | U_wall 0.49 · U_roof 0.35 · U_win 1.7 W/(m²·K) · g 0.63 · F_shade 0.60 | TABULA/EPISCOPE residential U-values (DE) and SEAI DEAP 4.3.1 glazing, frame (F_F = 0.7) and shading factors. |
| Thermal mass preset (C_m / A_m) | Medium · C_m 4,125 kJ/K · A_m 62.5 m² | ETH Zurich City Energy Analyst (ENVELOPE_MASS.csv, MIT) & Horvat & Dović (2016): Light 110 / Medium 165 / Heavy 300 kJ/(m²·K). |
| Solar geometry & sol-air | 5 m² (S) · α = 0.6, R_se = 0.04, F_W = 0.9 | Spencer (1971) / Sandia PVPMC solar position & isotropic sky irradiance (albedo 0.2); sol-air temperature (Bendjemila et al. 2026) & horizontal roof ΔR = 63 W/m² (Manyumbu et al. 2023). |
| People & internal gains | 2 × (70 W + 45 W) · 75 W (3 W/m²) | Occupants: 70 W sensible + 45 W latent (IDAE); 3 W/m² baseline (TABULA); home office 153 W (CTU/TUe); TV 98 W (EU 2019/2021); cooking 1,172 W (ENERGY STAR 4,000 BTU/h). |
| Hourly 5R1C heat balance | 1,625 W + 90 W = 1,715 W (n = 0.4 h⁻¹) | Method based on the simple hourly 5R1C model of EN ISO 13790 Annex C (ETH RC_BuildingSimulator) including cool-down after switch-on for part-day use & psychrometrics (Xu et al. 2026). |
| kW to BTU/h conversion | 1 kW = 3,412 BTU/h | NIST Special Publication 811 (International Table BTU = 1,055.05585262 J → 3,412 BTU/h per kW). |
| May–September electricity & cost | 808 kWh ÷ SEER 7.3 (SEER 6.10–8.49) × 37.97 ct/kWh | Hourly May–September cooling demand (PVGIS TMY) ÷ typical SEER/EER within the EU Regulation 626/2011 & 206/2012 class range (see table below); default Germany price 37.97 ct/kWh (Destatis H1 2026). |