Cooling capacity and electrical input on an AC datasheet
Read two ratings that both use kilowatts and check the test conditions behind a split system’s cooling figure.
Follow one system column
In the Mitsubishi Electric AP manual, the MSZ-AP25VG and MUZ-AP25VG pairing has a cooling capacity of 2.5 kW and electrical input of 0.60 kW at the stated rating point. The first value describes heat removed from the room per unit time. The second describes the electricity the system draws at that point.[1]
Carry over the test conditions
The same manual rates cooling at 27 °C dry bulb and 19 °C wet bulb indoors, with 35 °C dry bulb outdoors. A comparison needs the same mode, equipment combination and conditions. To size a system, ask the designer to compare its output at your design conditions with the room’s heat load.[1]
Read seasonal figures separately
The EU cooling label for this type of split air conditioner gives a design load in kW, a seasonal efficiency ratio (SEER) and a standardised annual energy figure in kWh. Use SEER to compare seasonal performance. For a household cost estimate you also need the local tariff and an assumption about use.[2]